AURORA-12S 12.1-inch 6 parameter patient monitor semi modular support ETCO2 2IBP Printer plug and play

 

 

5 Standard parameters: ECG, NIBP, SpO2, RESP, Temp

◆12.1-inch high resolution industry color TFT LCD display

◆Real time S-T segment analysis, pace-maker detection

Category: Brand:

Description

AURORA 12S vital sign monitor with touch screen & WiFi is suitable for monitoring patients’ vital signs and managing these parameters. The AURORA 12S vital sign monitor features a wide-range alarm setting & three priority levels with respective audio and visual indicators. It is designed to record, store, review, print, and generate alarms during patient hospitalization or home care.

Product Detail:

◆Indication of incorrect manipulation and malfunction analysis

◆Patient info input management function

◆Multi-lead ECG waveforms display in phase

◆Large volume of tabular and graphic trends information storage and easy to recall

◆Capture dynamic waveforms

◆Up to 2.5 hours working capacity of built-in rechargeable lithium battery

◆Unique accessory management cabinet

◆Networking capacity

◆Option: EtCO2, 5AH Lithium battery, wireless communication module (WIFI, GPRS), touch screen, IBP, AG, and thermal printer.

Accessories

Optional modular

Technique Parameter

Standard configuration

Screen

Display Type 12.1″ color TFT LCD
Resolution 800×600 pixels
Waveforms Up to 7

ECG

Input 3/5 wire ECG cable
Lead section I II III aVR, aVL, aVF, V
Gain selection *0.25, *0.5, *1, *1.2
Sweep speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Heart rate range 15-30bpm
Calibration ±1mv
Accuracy ±1bpm or ±1% (select the bigger data)

NIBP

Test method Oscillometer
Philosophy Adult, Pediatric and Neonate
Measurement type Systolic Diastolic Mean
Measurement parameter Automatic, Continuous measurement
Measurement method Manual mmHg or ±2%

SPO2

Display Type Waveform, Data
Measurement range 0-100%
Accuracy ±3% (between 70%-100%)
Pulse rate range 20-300bpm
Accuracy ±1bpm or ±2% (select the bigger data)
Resolution 1bpm

2-Temperature (Rectal & Surface)

Number of channels 2 channels
Measurement range 0-50℃
Accuracy ±0.2℃
Display T1, T2, ☒T
Unit  ºC/ºF selection
Refresh cycle 1s-2s

Respiration (Impedance & Nasal Tube)

Measurement type 0-150rpm
Accuracy ±1bm or ±5%, select the bigger data
Resolution 1rpm

Optional configuration

EtCO2-Plug & Play

Measurement type Side stream
Measurement range 0-10.0%; 0-76mmHg
Accuracy <5.0%, ±0.28kPa; ±2mmHg
>5.0%, ±10%

2-IBP (optional)

Measurement range 10~300mmHg
Number of channels 1 or 2 channels
Accuracy ±1mmHg or ±2%, select bigger data
Pressure tag ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP

12 leads ECG (optional)

Input 3/5/10 wires ECG cable
Lead section I, II, III aVR, aVL, aVF, V(V1-V6)
Heart rate range 15-380bpm
Calibration ±1mv